Description
Technical Specifications
| Technical Specifications | |
| Model Name | XSP5908 Series
XSP5916 Series |
| Network interface | |
|
Speed |
IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) – RJ45 version IEEE 802.3u 100Base-FX – SFP version |
| Connector ports | RJ45 x 6 (RJ45 version) SFP x 6 (SFP version) |
| Serial Interface | |
| Connector | D-Sub9 (DB models, supporting only 5-pin RS-232 mode) or 5.08mm 5-Pin Terminal block (TB Models) |
| Ports | 8 (XSP5908) or 16 (XSP5916) |
| Mode | RS-232/422/485 Software selectable |
| Serial port isolation | 3 kV isolation (SiS version only) |
| Baud Rate | 1,200 ~ 921,600 bps software selectable |
| Parity | None, Odd, Even, Mark, Space |
| Data Bits | 5, 6, 7, 8 software selectable |
| Stop Bits | 1, 2 software selectable |
| Flow Control | None, Xon/Xoff, RTS/CTS (RS-232 only) |
| Power | |
| Input Voltage | Redundant 24-48 VDC or Redundant 100-240 VAC/ 100-370 VDC (HV Series) |
|
Input Current |
0.73 A @ 24 VDC
0.35 A @ 100 VAC 0.20 A @ 100 VDC |
| Power Consumption | Approximately 20 W |
| Power Redundancy | Yes |
| Connector | 10-Pin Terminal Block |
| Reverse Polarity Protection | Yes |
| Physical Characteristics | |
| Housing | IP30 SPCC housing |
| Dimension (W x H x D) | 440.6 x 44 x 309 mm (1U Rack-mount) |
| Weight | 4 kg |
| Installation | 19” Rack mount (Rack-mount kit included) |
| Reset Button | Yes |
| Environmental Limits | |
| Operating Temperature Storage Temperature Ambient Relative Humidity |
-40°C~85°C (-40°F~185°F)
-40°C~85°C (-40°F~185°F) 5%~95%, 55°C (Non-condensing) |
| Software | |
| Protocols | IPv4, ICMP, TCP, UDP, DHCP Client, SNMPv1,v2c,v3, HTTP, HTTPS, Telnet, RFC2217, 802.1D-2004 RSTP, Security through OpenVPN Client/Server and IPsec (host-to-host or host-to-side) with up to 37.9Mbps VPN throughput, PPTP, and SMTP/TLS |
| Configuration | Agatel Management Utility, Web UI, Telnet, Console |
| VirtualCOM | Windows/Linux redirection software |
| Link Modes | |
| TCP Client | Single destination or VirtualCOM |
| TCP Server | 4 Connections; VirtualCOM or reverse Telnet |
| UDP | Up to 4 Ranges IP |
Regulatory Approvals
| Regulatory Approvals | ||||
| Safety | EN 61010-2-201 | |||
| EMC | FCC Part 15, Subpart B, Class B, EN 55032, Class B, EN 61000-6-2 Class B, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-4, IEC 61850-3 / IEEE 1613 | |||
| Test | Item | Value | Level | |
| IEC 61000-4-2 | ESD | Contact Discharge
Air Discharge |
±8kV
±15kV |
4
4 |
| IEC 61000-4-3 | RS | Radiated (enclosure) | 10 V/m | 3 |
| IEC 61000-4-4 | EFT | AC Power Port DC Power Port Signal Port |
±4.0KV
±4.0KV ±4.0KV |
4
4 4 |
| IEC 61000-4-5 | Surge | AC Power Port AC Power Port DC Power Port DC Power Port Signal Port |
Line-to Line±2.0KV Line-to Earth±4.0KV Line-to Line±1.0KV Line-to Earth±2.0KV Line-to Earth±2.0KV |
4
4 3 3 4 |
| IEC 61000-4-6 | CS | AC Power Port DC Power Port Signal Port |
10 V rms |
3 |
| IEC 61000-4-8 | PFMF | Enclosure | 100 A/m | 5 |
| IEC 61000-4-10 | Damped Oscillato- ry Magnetic Field | Enclosure | 100 A/m | 5 |
| IEC 61000-4-11 | DIP | AC Power Port | – | – |
| IEC 61000-4-12 | Damped Oscillatory | AC Power Port Signal Port |
2.5 KV common, 1 KV differential
2.5 KV common, 1 KV differential |
3
3 |
| Shock
Drop (Freefall) Vibration |
MIL-STD-810F Method 516.5
MIL-STD-810F Method 516.5 |
|||
| RoHS II | Yes | |||
| MTBF | XSP5916-6S-SI-HV: 9.18 years; XSP5916-6S-SI: 8.63 years | |||
| Warranty | 5 years | |||
| Model name | Description | Power | Ethernet | Serial |
| XSP5916-6S | Ind. 16 Port Serial Server, 100BASE-FX SFP slot, DB9 | 24~48 VDC |
6 (SFP) |
16 (DB9) |
| XSP5916-6S-TB | Ind. 16 Port Serial Server, 100BASE-FX SFP slot, TB5 | 16 (TB) | ||
| XSP5916-6S-SI | Ind. 16 Port Serial Server, 100BASE-FX SFP slot,Isolated | 16 (TB) | ||
| XSP5908-6S | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, DB9 | 8 (DB9) | ||
| XSP5908-6S-TB | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, TB5 | 8 (TB) | ||
| XSP5908-6S-SI | Ind. 8 Port Serial Server, 100BASE-FX SFP slot,Isolated | 8 (TB) | ||
| XSP5916-6S-HV | Ind. 16 Port Serial Server, 100BASE-FX SFP slot, DB9 | 100/240 VAC or 100/370 VDC | 16 (DB9) | |
| XSP5916-6S-TB-HV | Ind. 16 Port Serial Server, 100BASE-FX SFP slot, TB5 | 16 (TB) | ||
| XSP5916-6S-SI-HV | Ind. 16 Port Serial Server, 100BASE-FX SFP slot,Isolated | 16 (TB) | ||
| XSP5908-6S-HV | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, DB9 | 8 (DB9) | ||
| XSP5908-6S-TB-HV | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, TB5 | 8 (TB) | ||
| XSP5908-6S-SI-HV | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, Isolated | 8 (TB) | ||
| XSP5916 | Ind. 16 Port Serial Server, 10/100BASE-T(X) RJ45, DB9 | 24~48 VDC |
6 (RJ45) |
16 (DB9) |
| XSP5916-TB | Ind. 16 Port Serial Server, 10/100BASE-T(X) RJ45, TB5 | 16 (TB) | ||
| XSP5916-SI | Ind. 16 Port Serial Srv, 10/100BASE-T(X) RJ45,Isolated | 16 (TB) | ||
| XSP5908 | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, DB9 | 8 (DB9) | ||
| XSP5908-TB | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, TB5 | 8 (TB) | ||
| XSP5908-SI | Ind. 8 Port Serial Srv, 10/100BASE-T(X) RJ45, Isolated | 8 (TB) | ||
| XSP5916-HV | Ind. 16 Port Serial Server, 10/100BASE-T(X) RJ45, DB9 | 100/240 VAC or 100/370 VDC | 16 (DB9) | |
| XSP5916-TB-HV | Ind. 16 Port Serial Server, 10/100BASE-T(X) RJ45, TB5 | 16 (TB) | ||
| XSP5916-SI-HV | Ind. 16 Port Serial Srv, 10/100BASE-T(X) RJ45,Isolated | 16 (TB) | ||
| XSP5908-HV | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, DB9 | 8 (DB9) | ||
| XSP5908-TB-HV | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, TB5 | 8 (TB) | ||
| XSP5908-SI-HV | Ind. 8 Port Serial Srv, 10/100BASE-T(X) RJ45, Isolated | 8 (TB) | ||
| SDK Version | SDK Programmable version, ask HQ for information | – | – | 8/16 |
| Model name | Description |
| XDP-75-24 | 75W/3.2A DIN-Rail 24VDC power supply 88~264VAC / 124-370VDC input |
| GDC-120 | 120mm copper woven grounding cable |
| XCA-DB9-TB5 | Female DB9 to Female 3.81mm TB5 Converter |
| XTR-38-FM-2K | SFP Transceiver, 155Mbps, 1310nmLED, Multi-mode, 2km, 3.3V, -40~85C |
| XTR-38-FS-30K | SFP Transceiver, 155Mbps, 1310nmFP, Single-mode, 30km, 3.3V, -40~85C |