XTS8600 Series
IEC61850-3 Industrial NTP Server Grandmaster Clock

XTS8600 Series

IEC61850-3 Industrial NTP Server Grandmaster Clock

Key Features:

  • IEC 61850-3 HV & IEEE 1613 Certified NTP Server & IEEE 1588 PTP Grandmaster
  • -40 to +85 °C Operating Temperature, IP30 Protection, and Up to 5100 m Altitude
  • MIL-STD-810F Certified for Environmental and Transportation Reliability
  • Dual Power Inputs: DC (Built-in) or AC (via Adapter) with Wide Input Range
  • Full Redundancy Across Power, System, Network, and Link Layers
  • <40 ns PRTC-B/PTP, <50 μs NTP Accuracy, Calnex Verified
  • Excellent Holdover Performance: <0.5 μs/8 Hours / <72 μs/7 Days
  • Supports Power, Telecom, AVBTSN and Enterprise Profile
  • Three Ethernet Ports: Two PTP-Capable Combo Ports, All Three NTP-Capable
  • Supports Power, Telecom Profiles, AVBTSN and Media Broadcast Profiles
  • Dual Media Combo Ports Enable Cost-Effective Copper/Fiber Deployment
  • Supports Multi-Constellation GNSS with Anti-Jamming and Anti-Spoofing
  • Antenna Fault Detection and Protection: Short Circuit and Disconnection
  • Configurable IRIG-B (TTL, AM, RS-485), PPS, and 10 MHz Outputs

Description

Technical Specification

Model Name XTS8600/XTS8600I Series

GNSS Receiver Specifications

GNSS Input ports 1x GNSS Input; SMA (F) – active Antenna
GNSS Module specific Information Multi-Constellation Supported: GPS L1, GLONASS L1, BeiDou B1, Galileo E1 Maximum Concurrent Constellations: 3

 

Leap Second: Supported Sensitivity for GPS:

•  Tracking: -166 dBm

•  Reacquisition: -160 dBm

•  Cold Start: -148 dBm

•         Hot Start: -160 dBm

Acquisition Times Cold Start: < 45 seconds

Warm Start: < 7 seconds

Antenna Requirements 3.3 V, < 50 mA

Minimum gain=5dB; Maximum gain + Cable Attenuation ≤ 40dB

GNSS Vulnerability Mitigation Jamming: Support Detection, Warning and Switch to OCXO Holdover

Spoofing: Support Detection, Warning and Switch to OCXO Holdover (GNSS Antenna Only)

Antenna Vulnerability Mitigation Antenna Cable Short: Support Detection, Warning and Switch to OCXO Holdover

Antenna Disconnection: Support Detection, Warning and Switch to OCXO Holdover

Antenna Specifications (Accessories)

GNSS Antenna GNSS receiver: GPS L1, GLONASS L1, BeiDou B1, Galileo E1 LNA Gain: 40dB min

Weather-Proof Housing: IP69K

Operating and Storage Temperature: -40°C ~85°C

ESD: ±15KV Air Discharge

Mechanical size: 66.5 mm dia. x 21 mm H

MIL-STD-810F

Supply Voltage Range: 2.5 to 16VDC

GPS Antenna GNSS receiver: GPS L1, Galileo

Weather-Proof Housing: IP69K

Operating and Storage Temperature: -40°C ~85°C

ESD: ±15KV Air Discharge

Mechanical size: 66.5 mm dia. x 21 mm H

MIL-STD-810F

Supply Voltage Range: 2.5 to 16VDC

Anti Jamming GNSS Antenna GNSS receiver: GPS L1, GLONASS L1, BeiDou B1, Galileo E1 LNA Gain: 40dB Typ.

Weather-Proof Housing: IP69K

Operating and Storage Temperature: -40°C ~85°C

ESD: ±15KV Air Discharge

Mechanical size: 66.5 mm dia. x 21 mm H

MIL-STD-810F

Supply Voltage Range: 2.5 to 16VDC

Max. Antenna Cable Length Antenna cable:

Without amplifier:

LMR-400: 150M CFD-200: 50M RG58A/U: 25M

With Amplifier:

LMR-400: 250M CFD-200: 80M RG58A/U: 50M

Max. Sync-out Cable Length RG58 A/U Sync-Out cable:

1PPS, 10MHz, IRIG-B TTL: 150M

IRIG-B AM: 150M @1K impedance, 300M @10K impedance IRIG-B RS485: 1200M

Proven Clock Accuracy (Relative to UTC)

1PPS ±40 ns Peak *1
Demodulated IRIG-B ±40 ns Peak *1
Modulated IRIG-B AM ±1 μs Peak *1
RS-485 IRIG-B ±100 ns Peak *1
PTP Timestamp ±40 ns Peak *1
NTP Timestamp ±50 us Peak , ±40 us Average *1
Holdover accuracy – OCXO < 0.5 us / 8 hours / < 72 us / 7 days *2
  *1. Device locked to satellites for at least 24 hours.

*2. Device locked to satellites for at least 48 hours before holdover

Network Interface

Ethernet Standards IEEE 802.3 10BaseT

IEEE 802.3u 100BaseT(X)

IEEE 802.3ab for 1000BaseT(X) IEEE 802.3u for 100Base-FX IEEE 802.3z for 1000Base-X

Gigabit Ethernet Ports Two Combo ports, 2x 10/100/1000BASE-T(X) RJ45 or 2x 100/1000 Base-X SFP Support Synchronous Ethernet (SyncE) per ITU-T G.8261 ITU-T, G.8262 and G.8264 ESMC), PTP-Capable and NTP-Capable
Management Port 1x 10/100 BASE-T(X) RJ45, NTP-Capable

I/O

Console 1x DB9 Serial Console Port
SD Slot 1x micro-SD slot
Relay-Alarm Contact Rated Operational Voltage: 24 VDC

Continuous carrier: 1A Normal Open

Pickup time: 2.5ms

Turn-off time: 1ms

Sync-Out

Standard Sync-Out

(Sync 1, Sync 2)

Two configurable output channels (coaxial BNC (F) connector):

1. 10MHz (Square Wave)

2. 1PPS/PPM/PPH Output (Square Wave, configurable pulse width)

3.  IRIG-B TTL (Support IEEE1344 and C37.118.1)

4.  AFNOR French Time Code

BCD, BJT, ST and ST Checksum (Contact sales for these timecodes)

Extend Sync-Out (NTS8600I) (Sync 3 ~ Sync 6) Three extra configurable output channels

(Sync 3 ~ Sync 5, coaxial BNC (F) connector):

1. 10MHz (Square Wave)

2. 1PPS/PPM/PPH Output (Square Wave, configurable pulse width)

3. IRIG-B TTL B000~B007 (Support IEEE1344 and C37.118.1)

4.IRIG-B AM B120~B127 (Support IEEE1344 and C37.118.1)

5.AFNOR French Time Code

6.BCD, BJT, ST and ST Checksum (Contact sales for these timecodes) One extra standalone channel (Sync 6, TB3 connector)

IRIG-B RS-485 B000~B007 (Support IEEE1344 and C37.118.1)

Relay-Alarm Contact Rated Operational Voltage: 24 VDC

Continuous carrier: 1A Normal Open

Pickup time: 2.5ms

Turn-off time: 1ms

Electrical output Drive Levels

1PPS 5VDC 20 mA TTL compliant
IRIG-B TTL 5VDC 20 mA TTL compliant
Modulated IRIG-B 5Vp-p, 3.3:1 ratio, AM, Sinewave
RS-485 IRIG-B ±5 VDC IRIG-B Half-Duplex; 32 Transceivers Max. a bus

 

Frequency

Oscillator Advanced managed OCXO, with temperature drifting compensation

IEEE1588 Profiles

Default IEEE 1588V2 (PTPv2)

Default UDP (IEEE1588-2008 Annex D and J)

Default 802.3 (IEEE1588-2008 Annex F and J)

Power IEC/IEEE61850-9-3-2016 Power Utility Profile

IEEE C37.238-2011 Power Profile, with VLAN support

IEEE C37.238-2017 Power Profile, with VLAN support

Telecom ITUT-G.8265.1 Frequency

ITUT-G.8275.1 Phase/Time

ITUT-G.8275.2 Phase/Time

AVBTSN 802.1AS Profile
Enterprise Enterprise profile
*Media Broadcast

(In Development Plan)

SMPTE ST 2059-2

AES67 Media Profile

System Moods

GNSS Locked Mood Synchronizes time with GNSS signals for high accuracy
Handover Mood Maintains time using the OCXO clock after GNSS is unavailable
Free Run Mood Operates independently using RTC as the time source along with the OCXO clock

 

Functions

Network Synchronization RFC 1119 (NTPv2) Server

RFC 1305 (NTPv3) Server

RFC 5905 (NTPv4) Server

RFC 1769 (SNTPv3) Server

RFC 2030 (SNTPv4) Server

Network Protocols VLAN (IEEE 802.1q) filtering/tagging

IEEE 802.1p QoS

DSCP IPv4, IPv6 TCP, UDP

DHCP Client TACAS+/ RADIUS

Redundancy Devices Clustering (NTP Only)

PRP (IEC 62439-3)

Bonding – Active & Backup Bonding — LACP

Combo Ports

Management HTTP, HTTPS

SNMP v1/v2,v3

SSH/ Telnet (CLI), could be enabled/disabled Console CLI

Estimated Time Accuracy GNSS Status

Power Status PTP & NTP Status

SD/MMC Backup & Restore

Events & Alarms Event

Log

Syslog

Relay & Alarm Management

SNMP Trap

Physical Characteristics

Housing

Dimension (W x H x D)

Weight

Installation

SPCC w/Zinc Plated Body + Aluminum cover IP30 Metal Housing

252.8 x 220 x 44

2KG (AC + IRIG-B) / 1,9KG (DC + IRIG-B)

1U Rack-mountable or DIN-Rail Kits (Optional)

Power Supply

Rated Supply Voltage 110 – 240 VAC, 50/60HZ (XTS8600 AC series)

110 – 250 VDC (XTS8600 AC series)

24 – 60 VDC (XTS8600 DC series)

Input Voltage Range 85 – 264 VAC, 50/60 HZ (AC series)

88 – 300 VDC, (AC series)

19 – 66 VDC, (DC series)

Power Consumption Approximately 9.4 W (Max)

Environmental Limits

Operating Temperature

Storage Temperature

Operating Altitude

Ambient Relative Humidity

-40°C to +85°C (-40°F to 185°F)

-40°C to +85°C (-40°F to 185°F)

5100m

5% to 95% (Non-condensing)

Regularity Approvals

   Safety UL 62368-1 , CB IEC62368-1/EN62368-1 (UL Certified Operating Temperature: 75°C)

EMC

FCC(EMI): FCC Part 15, Subpart B, Class A

CE(EMI): EN 55032, EN61000-6-4, Class A

EN 61000-3-2 (Current Harmonics) EN

61000-3-3 (Voltage Flicker) CE(EMS): EN 55035, EN61000-6-2

CE(GNSS): EN 303 413. EN 301 489-19

   Power Automation IEC61850-3, IEEE 1613
Test Item Value Level
   IEC 61000-4-2 ESD Contact Discharge Air Discharge ±8KV

±15KV

4

4

   IEC 61000-4-3 RS Enclosure Port 10(V/m), 80-3000MHz

20(V/m), 80-1000MHz

3

IEC 61000-4-4

 

EFT

AC Power Port DC Power Port Signal Port ±4.0KV

±4.0KV

±2.0KV

4

4

Special

IEC 61000-4-5

 

 

Surge

AC Power Port AC Power Port DC Power Port DC Power Port Signal Port  

Line-to Line±2.0kV Line-to Earth±4.0kV Line-to Line±1.0kV Line-to Earth±2.0kV Line-to Earth±4.0kV

4

4

4

3

4

   IEC 61000-4-6 CS 0.15-80MHz 10V rms 0.15-80MHz, 80% AM 3
   IEC 61000-4-8 PFMF (Enclosure) 100A/m continuous, 1000A/m (3s) 5

IEC 61000-4-11

 

 

DIP

 

 

AC Power Port

30% reduction (Voltage Dips), 1 period

60% reduction (Voltage Dips), 50 period 100%, reduction (Voltage interruptions), 5 period

100% reduction (Voltage interruptions), 50 period

 

 

 

IEC 61000-4-16

Main Frequency Voltage DC Input Port Signal Port 30V Continuous, 300V 1s 30V Continuous, 300V 1s 4

4

   IEC 61000-4-17 Ripple DC Input Port 10% of unit 3

IEC 61000-4-18

 

Damped Oscillatory

 

AC Power Port

2.5KV common,

1KV differential mode @ 1MHz

 

3

Signal Port Telecommunication Port 2.5KV common,

1KV differential mode @ 1MHz

 

3

IEC 61000-4-29

 

DC Voltage Dips & Interruptions

 

DC Input Port

30% Reduction (Voltage Dips):0.1 sec 60% Reduction (Voltage Dips):0.1 sec 100% Reduction

(Voltage Interruption):0.05 sec

Shock Drop Vibration MIL-STD-810G Method 516.5

MIL-STD-810F Method 516.5

MIL-STD-810F Method 514.5 C-1 & C-2

RoHS2 Yes
MTBF 20 years
Warranty 5 years / Upgradable to 10 years
Physical Characteristics

Housing
Dimension (W x H x D) WeightInstalleation Power inputs
SPCC IP30 Metal Housing

223 x 251 x44 mm (not including screws and rack-mount kit) TBD

1U Rack-mountable

24-60 VDC(Dual Input) or 110-240VAC/12–240VDC

Environmental Limits
Operating Temperature Storage Temperature Ambient Relative Humidity -40°C to +70°C (-40°F to 185°F) / LCM display maximum 0 to +70 °C

-40°C to +75°C (-40°F to 185°F) / LCM display maximum -30 to +80 °C 5% to 95% (Non-condensing)

REGULATORY APPROVALS
Regulatory Approvals
Safety EN/IEC 62368
 

EMC

FCC Part 15, Subpart B, Class A, EN 55032, EN 61000-6-4:Class A, EN 61000-3-2, EN 61000-3-3
Power Automation IEC61850-3, IEEE 1613
Test Item Value Level
IEC 61000-4-2 ESD Contact Discharge Air Discharge Contact Discharge Air Discharge 4

4

IEC 61000-4-3 RS Enclosure Port Enclosure Port 3
IEC 61000-4-4 EFT AC Power Port DC Power Port Signal Port AC Power Port DC Power Port Signal Port 4

4

4

IEC 61000-4-5 Surge AC Power Port AC Power Port DC Power Port DC Power Port Signal Port AC Power Port AC Power Port DC Power Port DC Power Port Signal Port 4

4

4

3

4

IEC 61000-4-6 CS 0.15-80MHz 0.15-80MHz 3
IEC 61000-4-8 PFMF (Enclosure) (Enclosure) 5
IEC 61000-4-11 DIP  

AC Power Port

 

AC Power Port

 

IEC 61000-4-12 Damped Oscillatory AC Power Port AC Power Port 3
Shock Drop Vibration MIL-STD-810G Method 516.5

MIL-STD-810F Method 516.5

MIL-STD-810F Method 514.5 C-1 & C-2

RoHS2 Yes
MTBF TBD
Warranty 5 years
Model Technology Ethernet Ethernet/SFP Sync-Out Input Voltage
XTS8600-DC GPS 1 2 2 channels Dual 19-66 VDC
XTS8600-AC GPS 1 2 2 channels Single 85-264VAC or 88-300VDC
XTS8600I-DC GPS 1 2 6 channels Dual 19-66 VDC
XTS8600I-AC GPS 1 2 6 channels Single 85-264VAC or 88-300VDC