Description
Network interface
| Ethernet Port | 1x 10/100BASE-T(X) RJ-45 |
| Compliance | IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-T(X) |
Serial Interface
| Connector | 9-Pin D-Sub9 connector(Male, -DB version) or 5-Pin Terminal block (-TB version) |
| Ports | 1 |
| Mode | RS-232/RS-485(2 and 4 wire)/RS-422, software selectable |
| Baud Rate | 1200~230,400 bps (RS-485 4-wire allows up to 921,600 bps) |
| Parity | None, Odd, Even, Space, Mark |
| Data Bits | 7,8 |
| Stop Bits | 1,2 |
| Flow Control | None, Xon/Xoff, RTS/CTS (RS-232 only) |
Power Characteristics
| Connector | DC Jack |
| Input Voltage
Power Consumption Power Redundancy |
DC Jack 5VDC
<2W No |
| Reverse Polarity Protection | Yes |
Mechanicals
| Dimensions (W x D x H) | 65mm x 78mm x 28mm (without wall-mount part) XSC5201-TB: 88.5 x 78.3 x 27.8mm (with wall-mount part)
XSC5201-DB: 88.5 x 84 x 27.8mm (with wall-mount part and DB9 connector) |
| Installation | Wall-Mount or DIN-Rail (optional kit) |
| Reset Button | Yes |
| Weight | 185g |
Environmental Limits
| Operating Temperature | -40°C ~ 70°C (-40°F ~ 158°F) |
| Storage Temperature | -40°C ~ 85°C (-40°F ~ 185°F) |
| Ambient Relative Humidity | 5 ~ 95% RH, (non-condensing) |
Software
| Protocols | TCP, IPv4, UDP, DHCP Client, HTTP, HTTPS, Telnet, ARP, SNMPv1,v2c,v3 |
| Configuration | Agatel  Management Utility, Web UI, Telnet, CLI |
| VirtualCOM | Windows/Linux redirection software |
| TCP Client | Single destination or VirtualCOM |
| TCP Server | 4 Connections; VirtualCOM or reverse Telnet |
| UDP | Up to 4 Ranges IP |
 Regulatory Approvals Â
| Safety | EN 60950-1/EN62368-1 | |||
| EMC | FCC Part 15, Subpart B, Class A EN 55032,
EN 61000-3-2 EN 61000-3-3 EN 55024 |
|||
| Test | Item | Value | Level | |
| IEC 61000-4-2 | ESD | Contact Discharge Air Discharge | ±4kV ±8kV |
2
3 |
| IEC 61000-4-3 | RS | 80-1000MHz | 3(V/m) | 2 |
| IEC 61000-4-4 | EFT | AC Power Port DC Power Port Signal Port |
±1.0kV
±1.0kV ±0.5kV |
2
2 2 |
| Â
IEC 61000-4-5 |
Surge |
AC Power Port AC Power Port Signal Port |
Line-to Line±1.0KV Line-to Earth±2.0KV Line-to Earth±2.0KV |
3
3 3 |
| IEC 61000-4-6 | CS | 0.15-80MHz | 3 Vrms | 2 |
| IEC 61000-4-8 | PFMF | Enclosure | 1A/m | 2 |
| IEC 61000-4-11 |
DIP |
AC Power Port |
>95%,Reduction,0.5period
30%, Reduction,25 period >95%,Reduction,250 period |
– |
| Shock | MIL-STD-810F Method 516.5 | |||
| Drop | MIL-STD-810F Method 516.5 | |||
| Vibration | MIL-STD-810F Method 514.5 C-1 & C-2 | |||
| RoHS | Yes | |||
| MTBF | 54.58 years according to MIL-HDBK-217F, 25 degrees C | |||
| Warranty | 5 years | |||
| Model name | Description |
| XSC5201-DB | 1-Port Semi-industrial Serial Server, 10/100BASE-T(X), RS232/422/485 DB9 |
| XSC5201-TB | 1-Port Semi-industrial Serial Server, 10/100BASE-T(X), RS232/422/485 TB5 |
| Model name | Description |
| XPA-305-05-DC-LV6-US | DC jack (3.5/1.35/7.5 mm) power adapter, 100~240VAC input, 1.0A @ 5 VDC output, US plug, LV6 |
| XPA-305-05-DC-LV6-EU | DC jack (3.5/1.35/7.5 mm) power adapter, 100~240VAC input, 1.0A @ 5 VDC output, EU plug, LV6 |
| XPA-305-05-DC-LV6-UK | DC jack (3.5/1.35/7.5 mm) power adapter, 100~240VAC input, 1.0A @ 5 VDC output, UK plug, LV6 |
| XCA-DB9-TB5 | Female DB9 to Female 3.81mm TB5 Converter |
| ADP-DB9(M)-DB9(F) | SE_MB52XX DB9 Pin assignment to SE_MB50XX DB9 Pin assignment |
| XDK-25-P-SE | Plastic DIN Rail Kit |